Maximum security, customised solutions.
Permit-free installation Storage for Lithium-ion batteries
Cost-saving battery charging
Special design loading container for Lithium-ion batteries:
Technical details
- Walk-in REI / F90 fire protection storage with DIBt approval
- Permit-free installation
- Highly safe, fire-resistant and thermally insulated
- Flexible indoor or outdoor installation
- Individually customizable safety concepts
- Monitoring and automatic shutdown in the case of faults
- Transmission of errors and alarms
- Mobile data transmission and backend
- Loading capacities of up to 2000 loading operations per container can be realized
- Various design concepts: heavy-duty shelving, mounting plate, mobile loading racks, loading lockers
We do not offer you standard solutions. Instead, we develop loading containers that are perfectly tailored to your needs.
Individual adjustment of the load capacities
Use Cases
Versatile Application Areas
- Companies that use a large number of small to medium capacity batteries
- E-scooter, e-scooter or e-bike sharing models
- Road construction firms
- Garden and landscaping contractor
- Development of special solutions with individual requirements
security concepts
Overview of the security classes
Charging lithium-ion batteries involves a considerable risk of damage and therefore requires special attention in terms of safety. As the safety requirements vary depending on the application, we have developed a flexible safety concept that is divided into three safety classes.
True to our motto “Security that fits”, we offer individually tailored solutions and distinguish between the following security classes:
SafetyClass-Basic
Power socket switch-off via safety relay, monitoring of smoke detectors, emergency stop and room temperature, status display via signal tower, compliant with work and fire safety regulations.
SafetyClass-Advanced
Extended basic function with PLC signal processing, individual monitoring and shutdown of charging processes in the event of deviations, temperature monitoring and status display on 12'' HMI.
SafetyClass-Advanced-Pro
Enhanced Advanced function
with Circlesystem-integration,web-based dashboards, real-time analysis, reporting and e-mail alerts
oder SMS.
All security classes have the following security features
- Entrance door with panic lock
- Air-conditioning (heating & cooling)
- External marking and labeling in accordance with all legal requirements
- Implementation and realization of individual security concept (see security classes 1-3)
- Certified fire protection storage that can resist a fire inside or outside the container for at least 90 minutes
System description
Safety equipment for the loading container and individual extensions

Battery loading container
Walk-on REI90 / F90 fire protection storage with DIBt approval, can be flexibly installed on concrete surfaces. Dimensions: 2.82 m × 2.58 m × 2.911 m (can be extended in 1.20 m increments). Equipped with hot-dip galvanized drip tray, anti-panic fire door.
Anti-Panik-Brandschutztür.

Basic equipment loading container
Integratable fire protection system with multi-sensor detector, emergency stop and signalling column, lighting, service socket, air conditioning (+20°C summer, +5°C winter), technical ventilation, control cabinet and 16A protective contact customer interface.

Optional equipment loading container
Automatic door hold-open system, temperature and door position monitoring, additional emergency stop in the entrance area, motion detector and intelligent sockets for the monitoring of each charging process.
Safe use of lithium batteries
Service
For the realization of your tailor-made charging infrastructure
You too can benefit from over 30 years of expertise in the field of automation and special machine construction. Since 2020, we have been developing charging containers that are tailored to the needs of charging lithium-ion batteries.
No matter how demanding your requirements are - we will implement the project efficiently, innovatively and reliably.
Individual software solutions
Customization of the load management system according to your requirements.
Comprehensive service
Comprehensive planning, professional assembly, precise installation, thorough commissioning, and detailed user instruction.
Technical precision
Pre-measurement of your charging parameters, including devices and batteries, to ensure optimum efficiency.
Training and support
Training in the operation of the load management system and annual safety briefings.
Regular safety and functional checks
DIN VDE 0105-100 and DGUV 3 inspections with software/firmware updates.
Flexible solution
Data storage enables simple evaluation and adaptation to changing requirements.
FAQ
Most frequently asked questions
The loading container basically consists of a certified F90 / REI 90 fire protection container with DIBt approval.
In most federal states, no building permits or other permits are required. However, this depends on the state building regulations of the respective federal state where the loading container is to be installed and depends on the container size.
The loading container may only be set up on flat and paved surfaces (e.g. concrete slab) that are suitable for the weight of the loading container. The selection of concrete in terms of load-bearing capacity, usability and durability according to DIN EN 206 must be determined in accordance with local requirements and conditions.
Auf Grund der Korrosionsgefahr darf der Boden nicht magnesihaltig sein.
There are no special requirements regarding the minimum distances to be maintained for the loading container. The general regulations of the respective state building regulations apply.
Furthermore, a service distance of at least 1 meter from adjacent buildings or facilities is recommended.
In its standard version, the loading container has the following interfaces:
- Terminal strip for supply cable (power cable)
- Terminal strip for signal exchange (control cable)
- Grounding rail for integration into the customer's grounding concept
Der Ladecontainer verfügt standardmäßig über einen Anschlusspunkt ausgelegt für 100A. Dies kann jedoch in beide Richtungen (z.B. 63A oder 150A) angepasst werden und richtet sich nach der Anzahl und der der Leistungsaufnahme der eingesetzten Ladepripherie.
The loading container has a basic dimension of W=2.82m x D=2.58m x H=2.91m (without attachments) and can be expanded in depth in increments of 1.20m.
The loading container has the following features:
- Walk-in REI / F90 fire protection storage with DIBt approval
- Permit-free installation
- Flexible indoor and outdoor installation
- Active charging management
- Individually customizable safety concepts
- Monitoring and automatic shutdown of charging processes in the event of errors
- Transmission of errors and alarms
- Mobile data transmission and backend
- Loading capacities of up to 2000 loading processes per loading container have already been realized
In addition to our standard solutions, we also develop loading containers that are perfectly tailored to individual customer requirements.
Each loading container has the following basic equipment:
- Walk-in REI / F90 fire protection warehouse with DIBt approval with galvanized drip tray and anti-panic fire protection door
- Connection box on the outer back of the container as a connection point for customer supply lines
- Interior lighting
- Fire protection system
- Air conditioning (cooling and heating)
- Technical ventilation
- Signal tower outside the entrance area
- Emergency stop on the control cabinet inside the container
- 16A protective contact sockets as an interface for customer charging peripherals
- Customer-oriented storage and loading concept (heavy-duty racking, assembly wall, mobile loading racks or loading lockers)
- 16A service socket in the inner entrance area
The basic equipment of the loading container can be expanded with the following additional functions:
- Automatic door hold system
- Smart sockets for monitoring every single charging process
- Room temperature monitoring
- Door position monitoring
- Motion detector inside the container
- Additional emergency stop in the outer entrance area
- Outdoor lighting
Charging lithium-ion batteries involves a considerable risk of damage and therefore requires special attention in terms of safety. As the safety requirements vary depending on the application, we have developed a flexible safety concept that is divided into three safety classes.
True to our motto “Security that fits”, we offer individually tailored solutions and distinguish between the following security classes:
- SafetyClass – Basic
- Socket shutdown via safety relay
- Monitoring of fire alarm system, emergency stop and room temperature
- Status display via signal tower
- Compliant with work and fire safety regulations
- SafetyClass – Advanced
- Extended basic function with PLC signal processing
- Individual monitoring and switching off of charging processes in the event of deviations
- Status display on 12'' HMI
- SafetyClass – Advanced-Pro
- Advanced advanced function with our CIRCLE system
- Web-based dashboards, real-time analysis and reporting
- Alerts via email or SMS
Loading concepts with 30 to 2,000 loading processes per loading container have already been implemented.
However, the number of charging processes depends on the customer's charging peripherals and depends on the respective dimensions and performance data of the equipment used.
Depending on the design of the loading container, the operating data or status displays in the loading container itself can be read on a 12" HMI on the control cabinet or on the web.
Each loading container has a signal tower with an acoustic detector in the outer entrance area that indicates the status accordingly. In addition, the charging container offers an electrical interface (potential-free contacts) for connecting collective messages for warnings and alarms.
Depending on the design of the loading container, pre-defined people can be informed accordingly via SMS or email in the event of an error.
Our charging container is suitable for all applications in which lithium batteries with low or medium performance are used and must be safely stored and charged in larger quantities.
Die Lieferzeit ist abhängig von der Ausführung. In der Standardausführung beträgt die Lieferzeit inklusive Lieferung, Montage und Inbetriebnahme ca. 22-24 Wochen.
All external supply lines are connected to the connection box on the outside back of the charging container.
The following services must be provided on site:
- Provision and testing of suitable installation space
- Connection of supply lines to the connection box
- Connection of foundation earthing to earthing bar
- (Optional) Connect network cable to the connection box
- (Optional) Connection of signal cable to the connection box
The following template can be used to prepare for a consultation:
- General information about the installation location
- Address of installation location
- Information about the electrical connection point
- Requirements regarding loading processes and storage capacities
- Number of batteries to be taken into account
- Maximum permissible working height for storing the batteries
- Information about charging management: How many batteries should be charged, when and in what order
- Information about charging peripherals
- Dimensions charger and battery
- Mains voltage charger
- Mains power charger
- Heat loss power charger
- Heat loss performance of batteries
- Are there communication interfaces for data transfer?
- Safety
- Should the 16A protective contact sockets be electrically protected individually or in groups?
- Should the charging processes be monitored individually?
- Should the status display be on a 12'' HMI?
- Should a web-based real-time analysis with reporting be implemented?
- Should an error be sent via SMS?
- Should an error be reported by email?
- Specifications regarding technical equipment
- Are additional functions desired in addition to the basic equipment?
- Handling data
- Would you like to be able to access all operating data, error messages and alarm messages on the web?
- Should all operating data, error messages and alarm messages be stored on a server?
- Exchange with fire department
- Has there been an exchange with the fire department regarding the construction project and does this result in further requirements for the loading container?